- +1 305 988 8996
- Mon - Fri: 9:00 - 18:30
GZ ORTHOPEDICS nails, plates, and pedicle screws are made of continuous carbon fibers reinforced polymer.
The Polymer (PEEK) adhere the fibers together.
The continuous carbon fibers are layered in a unidirectional, longitudinal orientation, as well as in helical / diagonal orientation.
about the product
GZ ORTHOPEDICS “Piccolo” nails & plates are made of continuous carbon fibers reinforced polymer. The continuous carbon fibers are woven in a unidirectional orientation at the core of the nail. The core is wrapped by additional helical fibers. The GZ ORTHOPEDICS “Piccolo” plates are made out of continuous carbon fibers in longitudinal as well as diagonal orientation.
The GZ ORTHOPEDICS implants allow CT & MRI scans with no/minimal artifacts caused by the carbon fibers implant. Clear imaging of the soft tissue surrounding the bone is advantageous in pathological cases.
In comparative fatigue experiments of Ø8.5mm nails, a Titanium rod failed after 40,000 cycles, a Stainless Steel rod failed after 440,000 cycles, and the CarboFix nail did not fail even after 4,000,000 cycles.
GZ ORTHOPEDICS implants are radiolucent, offering improved fracture and tissue imaging intra-op & post-op. The fracture line can be seen clearly through the implant which does not disrupt the view.
The modulus of elasticity of the composite material is close to that of cortical bone. This might lower the risk for stress risers and secondary fractures, as well as to contribute to early fracture healing.
Intramedullary nails for Humerus, Tibia & Femur, as well as Ankle Arthrodesis nail
Plates for Distal Radius, Proximal Humerus & Distal Fibula and others.
WhatsApp us
Made of continuous carbon fibers reinforced polymer.
Poly-Axial Screw Design – 15° trajectory variation.
Bone / screw interface: Ultrathin Titanium Shell
for better bone integration.
MRI & CT: No artifacts.
Oncology: Essential in radiation therapy:
No backscattering.
No attenuation.
Precise radiation planning.
Unparalleled Fatigue Strength.
Optimal Modulus of Elasticity.
Radiolucent: Allows effective follow-up.
Made of continuous carbon fibers reinforced Polymer
The plate is anatomically shaped
Universal design for Right & Left Humerus
Low profile: plate thickness 3.7mm
Circumference radiopaque marking outlining plate contour for positioning & follow-up
CarboFix Proximal Humerus plates are FDA cleared and CE marked
Features
Radiolucent: Superior fracture imaging
Unparalleled fatigue strength
Improved modulus of elasticity
No cold welding
Made of continuous carbon fibers reinforced polymer
The Distal Femur plates are anatomically shaped
Screw holes accommodate both locking and non-locking screws
Circumference radiopaque marking outlining plate contour for positioning
CarboFix Distal Femur plate is FDA cleared and CE marked
Poly-Axial locking screws – up to 10° trajectory variation
Made of continuous carbon fibers reinforced polymer
The nail have a 5° proximal anteversion
Ultra-thin titanium shell coating of the lag screw
The nail cap is made of composite material and is radiolucent
Radiopaque markers around the drill holes and along the nails’ length
axis facilitate positioning and drilling
Lag Srcew and the long Nail are cannulated
CarboFix Piccolo Proximal Nail is FDA cleared and CE marked
Made of continuous carbon fibers reinforced polymer.
The nail has a 9° bending at its proximal end.
The screw holes are threaded for enhanced screw fixation.
CarboFix Tibia nails are cannulated for insertion over a proprietary
2.4mm guide wire.
The nail cap is made of composite material and is radiolucent.
Radiopaque markers around the drill holes and along the nails’ length
axis facilitate positioning and drilling.
CarboFix Tibia nails are FDA cleared and CE marked.
Made of continuous carbon fibers reinforced polymer.
The nails are shaped as an anatomical bow, representing a radian of 1.5
meters (apart for the 200mm nails, which are not curved).
The screw holes are threaded for enhanced screw fixation.
CarboFix Femur nails are cannulated for insertion over a proprietary
2.4mm guide wire.
The nail cap is made of composite material and is radiolucent.
Radiopaque markers around the drill holes and along the nails’ length
axis facilitate positioning and drilling.
CarboFix Femur nails are FDA cleared and CE marked.
Made of continuous carbon fibers reinforced polymer.
The carbon fibers are arranged in a unidirectional longitudinal
orientation, as well as in a diagonal orientation, allowing multidirectional strength in all planes.
Narrow & Broad designs are available
Radiolucent: clear view of the fracture site
Circumference radiopaque marking outlining plate contour for
positioning & follow-up.
Polyaxial locking screws – up to 10° trajectory variation.
Screw holes accommodate both locking and non-locking screws.
CarboFix Diaphyseal Plates are FDA cleared and CE marked.
Made of continuous carbon fibers reinforced polymer.
The carbon fibers are arranged in a unidirectional longitudinal orientation, as well as in a diagonal orientation, allowing multidirectional strength in all planes.
Radiolucent: Clear view of the fusion site.
Nail internal Tibiotalar compression mechanism up to 7mm.
External compression up to 30mm using the Insertion Handle.
The screw holes have an inner thread for enhanced screw fixation to the nail.
The nail cap is made of composite material and is radiolucent.
Radiopaque markers around the drill holes and along the nails’ length axis facilitate positioning and drilling.
CarboFix Ankle Arthrodesis nails are FDA cleared and CE marked.
Made of continuous carbon Fibers reinforced polymer.
Two types of Fibula plates are available:
– Anatomical Distal Fibula plate.
– One Third Tubular plate.
Low profile: plate thickness 2.3mm.
Polyaxial locking screws – up to 10° trajectory variation.
Screw holes accommodate both locking and non locking screws.
Circumference radiopaque marking outlining plate contour for positioning & follow-up.
CarboFix Fibula plates are FDA cleared and CE marked.
Made of continuous carbon fiber reinforced polymer.
Low profile: plate thickness 2.0mm.
Thread-less screw holes, thus the screw creates its own thread
Polyaxial locking screws – up to 10° trajectory variation.
Screw holes accommodate both locking and non locking screws.
Circumference radiopaque marking outlining plate contour for positioning & follow-up.
CarboFix Fibula plates are FDA cleared and CE marked.
Made of continuous carbon fiber reinforced polymer.
Low profile: plate thickness 2.0mm.
Thread-less screw holes, thus the screw creates its own thread
Polyaxial locking screws – up to 10° trajectory variation.
Screw holes accommodate both locking and non locking screws.
Circumference radiopaque marking outlining plate contour for positioning & follow-up.
CarboFix Lapidus plate is FDA cleared.
Made of continuous carbon Fibers reinforced polymer.
Two types of Fibula plates are available:
– Anatomical Distal Fibula plate.
– One Third Tubular plate.
Low profile: plate thickness 2.3mm.
Polyaxial locking screws – up to 10° trajectory variation.
Screw holes accommodate both locking and non locking screws.
Circumference radiopaque marking outlining plate contour for positioning & follow-up.
CarboFix Fibula plates are FDA cleared and CE marked.
1Besides the Spraypen®, the Vivostat® system offers different types of applicators, e.g. the Endoscopic Applicator. For a full list of application devices click here